Resilmount MBFR Sound Isolation Clips

Resilmount MBFR clips are resilient sound isolation clips for use in wall soundproofing applications where wall studs may be uneven. The notches in the MBFR clip allow extra tolerance in the placement of furring channel so that the resulting wall will be even and unbowed, despite any issues in the position of the wall studs.

MBFR clips are an excellent solution for decoupling a wall from the building's frame, preventing sound from traveling from one room to another. This means that MBFR clips can be used with confidence in homes, sound studios, offices, theaters, or anywhere else that needs soundproofing.

MBFR clips are not manufactured for use in ceilings.

Resilmount MBFR Specifications
 
Resilmount's patented thermoplastic rubber outperforms standard rubber because of its unique natural absorbing characteristics. Resilmount's unique sound cell design guards against structure-borne vibrations transferring into the body of the Resilmount because of its strong column design providing a small percentage of contact surface are
a with the structure or substrate it is fixed to. This aids in absorbing and breaking up airborne sound at its transfer point.Resilmount MBFR Specficiations

MBFR Specifications
Width: 1 - 3/8 in.
Height: 4 - 7/8 in.
Depth: 1 - 7/16 in.
Weight: 0.25 lbs
Max Spacing Between Clips: 48 in. on center

Furring Channel Specifications
Minimum: 25 Gauge
Depth: 7/8 in. or 1 - 1/2 in.
Width at Top: 1 - 1/4 in.
Width at Bottom: 2 - 1/2 in. max

Resilmount MBFR Installation Guide

Wall Installation Guide
Resilmount MBFR Wall Installation Diagram
NOTES

Use 25 gauge furring channel on walls.
Furring channel is installed across studs horizontally.
Use a 4 ft. level to ensure furring channel is installed level.
Clips are spaced no further than 48 inches apart horizontally
Hat channel must not be spaced more than 24 inches vertically
Bottom clips must be less than 3 inches from the floor
Top clips must be less than 6 inches from the ceiling
Make sure to leave a 1/4 in. gap between wall and celling and wall and floor to fill with acoustical caulk.


STEP 1 - INSTALL THE CLIPS
Measure for placement of Resilmount MBFR isolation clips using layout guidelines listed in the Installation Notes above.
Mark locations and place clips against the stud. Place washer on clips and install screw through the hole in the center of the clip.

STEP 2 - INSTALL THE FURRING CHANNELResilmount MBFR Installation Picture
Snap furring channel into clips.
Some walls will require you to overlap hat channel. It is best to overlap 6 inches of hat channel between two clips. Secure the hat channel with two 7/16 framing screws or 18 gauge tie-wire.

STEP 3 - INSTALL THE DRYWALL
Place shims on the floor to allow spacing between the drywall and the flooring. This ensures decoupling from the floor to make it impossible for vibrations to travel from the wall to the floor and vice-verse.
Screw drywall in place through hat channel. Be sure drywall is fully installed before removing shims from underneath.

STEP 4 - SEAL THE PERIMETER
Use acoustical sealant to fill the 1/4" gaps around the perimeter, and all gaps around electrical boxes, windows, and doors.