0 item(s) / Total: $0
Resilmount MBF
Resilmount MBF
Resilmount MBF
SKU: 55-MBF-W
Resilmount MBF
Your Price:
$5.29
Your Price: $2.50
Standard Drywall Wall Installation
A basic wall installation with noise reduction in mind. Acoustical sealant prevents sound from traveling through gaps in materials and sound rated insulation helps to prevent sound from passing through walls.
Noise Reduction Upgrade Wall Assembly
Green Glue is an excellent option for soundproofing walls. Apply a layer of Green Glue between two layers of drywall to significantly reduce sound propagation through walls. Acoustical sealant adds a finishing touch to the project.
High Performance Green Glue Noise Reduction Assembly
For superior soundproofing, add two layers of Green Glue between three layers of drywall. Green Glue dissipates sound into heat through molecular viscoelasticity. 5/8" drywall adds more mass than 1/2" drywall, providing more soundproofing.
Premium Wall Assembly With Green Glue And Clip Assembly
Clips and channels mechanically separate the walls from the building structure. Separation prevents sound from traveling through the structure itself. A clip assembly combined with a Green Glue application gives superb soundproofing for high, mid, and low frequencies.
Ultimate Soundproofing Wall Assembly
The ultimate wall assembly utilizes two layers of Green Glue with a clip and channel assembly and acoustical sealant to seal any gaps. Use all available options to maximize the amount of noise reduction.
Resilmount MBF Sound Isolation Clips

Resilmount MBF clips are furring channel clips for use in wall applications where wall studs may be uneven. MBF clips are a budget conscious/low cost choice for projects where sound isolation is not critical. MBF clips' simple notched design provides extra tolerance for the placement of furring channels to create a straight and even channel even when the wall studs are not all directly in line.

MBF clips in conjunction with furring channel can provide separation between the wall and building frame, which can help in acoustically isolating a room. Additionally MBF clips can act to create some space between the drywall and studs which can be used to run plumbing or electrical conduit.

MBF clips are not manufactured for use in ceilings.

Resilmount MBF Specifications
 
Resilmount MBF clips are a budget friendly mounting bracket for resilient or standard furring channels, for reducing airborne vibration and structure-borne vibration in wall and ceiling applications. The MBF's simple design makes it adaptable to hundreds of applications. MBF clips are manufactured under the ISO9001 quality control system.

MBFR Specifications
Width: 1 - 3/8 in.
Height: 4 - 7/8 in.
Depth: 1 - 1/16 in.
Weight: 0.2 lbs
Max Spacing Between Clips: 48 in. on center

Furring Channel Specifications
Minimum: 25 Gauge
Depth: 7/8 in. or 1 - 1/2 in.
Width at Top: 1 - 1/4 in.
Width at Bottom: 2 - 1/2 in. max

Resilmount MBF Installation Guide

Wall Installation Guide
Resilmount MBFR Wall Installation Diagram
NOTES

• Use 25 gauge furring channel on walls.
• Furring channel is installed across studs horizontally.
• Use a 4 ft. level to ensure furring channel is installed level.
• Clips are spaced no further than 48 inches apart horizontally
• Hat channel must not be spaced more than 24 inches vertically
• Bottom clips must be less than 3 inches from the floor
• Top clips must be less than 6 inches from the ceiling
• Make sure to leave a 1/4 in. gap between wall and ceiling and wall and floor to fill with acoustical caulk.


STEP 1 - INSTALL THE CLIPS
Measure for placement of Resilmount MBF isolation clips using layout guidelines listed in the Installation Notes above.
Mark locations and place clips against the stud. Install screw through the hole in the center of the clip.

STEP 2 - INSTALL THE FURRING CHANNELResilmount MBF Installation Picture
Snap furring channel into clips.
Some walls will require you to overlap hat channel. It is best to overlap 6 inches of hat channel between two clips. Secure the hat channel with two 7/16” framing screws or 18 gauge tie-wire.

STEP 3 - INSTALL THE DRYWALL
Place shims on the floor to allow spacing between the drywall and the flooring. This ensures decoupling from the floor to make it impossible for vibrations to travel from the wall to the floor and vice-verse.
Screw drywall in place through hat channel. Be sure drywall is fully installed before removing shims from underneath.

STEP 4 - SEAL THE PERIMETER
Use acoustical sealant to fill the 1/4" gaps around the perimeter, and all gaps around electrical boxes, windows, and doors.

Resilmount MBF Downloads

For more details on Resilmount MBF mounting clips, please reference our PDF downloads below: